What certifications should you look for when selecting fire duct wraps in the UAE?

 In commercial, residential, and mixed-use buildings across the UAE, fire protection standards are getting tighter, and for good reason. HVAC ducts, especially those running through fire-rated compartments or between floors, can become weak points in passive fire protection if not properly insulated.


That’s where fire-rated duct wrap insulation comes into play. These specially engineered wraps are designed to prevent the spread of fire and smoke through ductwork during emergencies. However, not all fire wraps are made the same, and selecting the right product starts with understanding certifications.


If you're sourcing fire protection materials, here’s what you need to know when evaluating fire-rated insulation for ducts in UAE based projects.


Why certification matters for fire wraps

Fire wraps aren’t just insulation, they are part of a building’s life safety system. In the event of a fire, these materials must:


  • Contain high temperatures within the duct

  • Prevent collapse or breach of duct walls

  • Slow or stop the spread of smoke and flames


Without proper certification, a fire wrap may not meet the performance expectations required by Dubai Civil Defence (DCD), international codes, or third-party inspectors.


Top certifications to look for

When selecting fire-rated duct wrap insulation, check for the following key certifications and standards:

1. UL 181 and UL 723

These are critical for materials used in air ducts. UL 181 relates to flame spread and smoke development, while UL 723 (ASTM E84) tests the surface burning characteristics of insulation materials. Products with these certifications ensure minimal contribution to flame propagation.


2. BS 476 Part 24

This British Standard assesses the fire resistance of ducts and ducting systems. Commonly accepted in UAE projects, this certification confirms that a wrap can maintain its structural and fire-resistant integrity during fire exposure.


3. ASTM E2336 / ISO 6944

These standards test fire resistance in ventilation duct enclosures. They’re especially important for kitchen exhaust systems or ducts passing through fire-rated compartments. Compliance with ISO 6944 (Type A and Type B ducts) is increasingly a requirement on DCD-approved material lists.


4. Dubai Civil Defence (DCD) product approval

All fire-rated insulation used in UAE buildings must be approved by DCD. Working with certified local fire-rated insulation suppliers ensures your product meets UAE-specific regulations and installation guidelines.

Why it’s not just about the product

Even a certified product can fail if not installed correctly. That’s why it's important to source from experienced insulation providers who not only offer tested fire wraps but also provide:


  • Manufacturer-backed technical data sheets

  • Approved installation methods

  • Coordination with MEP and fire consultants


This ensures your fire-rated duct wrap insulation performs exactly as it’s certified to and passes inspections without delay.


Final thoughts: Fire protection that stands up to scrutiny

In the UAE’s regulatory environment, every fire barrier matters. Choosing certified fire-rated insulation isn’t just about ticking a compliance box, it’s about safeguarding property, people, and long-term performance.


Make sure your materials are tested, approved, and supported by trusted suppliers who understand both international and local standards. It’s the only way to ensure that your fire duct wrap system does its job when it matters most.